32dba6af2cec13d3388469fef897748a1fce4859
27
Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
c6cf9bcb5e
|
Report discovered printers to the cloud, off by default
The gateway could already find printers; only a human reading a terminal could see the result. So adding a printer in the web console still began with walking to a machine to read its IP address off the screen. Now a background task scans on a timer and sends a `discovered_printers` frame. It cannot finish the job - the credential is on that screen and no probe can read it - but it removes the address, the serial and the guesswork about which vendor the thing is. OFF by default, which is the load-bearing part of this commit. A /24 sweep is 254 TLS handshakes and up to three HTTP requests per host, and nothing watching can tell that from a port scan; on a corporate network, being indistinguishable from a port scan is itself the problem. A gateway that did this by default would scan networks its operator never meant to point it at, and the first they would hear of it is from their own security team. So: - `discovery.enabled` is false unless set, per gateway, in that gateway's own config. The cloud cannot switch it on. A setting whose whole purpose is to bound what this process does to the local network has to be decided where that network is understood, which is not in a data centre. - `subnets` is explicit, never derived from this host's interfaces, so a second NIC, a VPN or a container bridge cannot widen the sweep. Anything wider than a /24 is still refused, now at config-import time rather than when the timer first fires. - A flag that is neither `true` nor `false` is an error, not a shrug. The two readings of a typo are not equally safe. - Naming a subnet without setting `enabled` scans nothing - the safe reading of an incomplete instruction - and `enabled` with nowhere to look is refused as the mistake it is. - The env var can switch it *off* over a file that enables it, which is the direction that has to work: a Proxy Box's config is signed in the cloud, so an operator who finds their gateway probing cannot just edit it. What a scheduled scan will not do, unlike the example CLI: send `M115`. Opening a serial port toggles DTR, which reboots an Arduino-based board and ruins a print in progress. The example can do it behind `--yes-reset-the-printer` because a human is standing there; a timer has nobody to ask, so it does not get the option and reads sysfs instead. Two things that took more care than expected: `Scan::looked()`. An empty report means "this gateway looked and its network has no unconfigured printers", so sending one after every probe failed would state something untrue about the farm. A partial failure is still evidence, though - withholding a good sweep because a container can never bind SSDP would suppress it forever - so the test is "did anything succeed", not "did everything". `fleet::configured()` reads the fleet file at parse level rather than through `load`, because the entry it most needs to recognise is the one `load` refuses: a printer discovery suggested, pasted in, with the access code not yet typed in. Re-offering that printer as a fresh find is noise at the one moment the operator is mid-way through adding it. Verified against the real LAN: a sweep found both printers by TLS certificate with correct serials and no credentials, and the frame it produced validates against the backend's EdgeClientMessageSchema. The `wire` subcommand on the example prints exactly that frame, and the capture is pinned as a backend fixture. SSDP remains untestable here - this container is a router hop from the printers and multicast does not cross one. |
||
|
|
da28597eeb
|
Report the OctoPrint API as what it is, and let the operator name it
Reporting a detected printer as `prusa_link` asserted a product nothing on
the wire mentions. What a probe observes is that something speaks the
OctoPrint REST API; PrusaLink is one implementation of it, OctoPrint itself
is another, and without a credential the two are indistinguishable - every
PrusaLink identity endpoint requires digest auth.
So discovery now reports `vendor = "octoprint"`, the protocol it actually
saw, and carries `ambiguous_with` so the rendered entry prints a comment
offering `prusa_link` directly above the `vendor` line. Changing it is a
one-word edit in the file the operator is already pasting into, which is the
right place for a question only they can answer. The exception is a body
that names itself: `/api/version`'s `text` field reads "PrusaLink 0.7.0" or
"OctoPrint 1.9.3", so on the rare unauthenticated 200 the answer is known
and no choice is offered.
For that to mean anything, `octoprint` had to become a vendor `fleet.rs`
accepts - otherwise discovery printed a block that would not load. It maps
to the same client as `prusa_link`, because they speak the same API, with an
`OctoPrintFlavour` recording which. The flavour is stored now, while the
client is still a stub, precisely because no probe can settle it: it is the
operator's answer, and without somewhere to keep it the real client would
have to ask them a second time. `PrusaLinkPrinter` is accordingly now
`OctoPrintPrinter` - one client for the API family - since a struct called
PrusaLink holding a flavour that says "Generic" is a contradiction someone
would later have to unpick.
**Found by the new test, and the reason it exists:** `fleet::load` did *not*
reject an entry whose credential was blank. `require_field` took an
`Option`, so `access_code = ""` arrived as `Some("")` and loaded happily -
which falsified the claim this feature was built on, that printing a block
with an empty credential is safe because pasting it in unfinished fails
loudly at startup. It does now. An empty credential is not a usable one; it
only moves the failure somewhere worse, where a Bambu printer is refused at
MQTT and a PrusaLink one 401s on every poll with nothing saying the field is
blank. This is the same trap as `??`-instead-of-`||` on an environment
variable that ships empty, which the backend's `auth/edge_secret.ts` and
`s3/index.ts` both document; it bites identically on a TOML key.
tests/discovery_to_fleet.rs is new and closes the loop: discovery and fleet
are coupled by nothing but a string, unit tests on either side cannot catch
a drift between them, and the symptom of a drift is an operator pasting in
exactly what they were told to and the gateway refusing to start. It renders
a candidate for every vendor, fills in the credential the way a human would,
loads it for real, and checks the handle matches the vendor asked for - not
merely that something loaded, since `octoprint` and `prusa_link` share a
client and a mapping that collapsed them would still load and still be
wrong.
Verification: the Moonraker probe now runs end to end over real HTTP against
a stand-in serving Moonraker's documented `/printer/info`, and correctly
reports a klipper entry named from the returned hostname. Port 80 cannot be
bound without root here, so the PrusaLink path is covered by a test that
takes a real socket answering a real digest challenge - the one link unit
tests on the classifier cannot reach, and the one PrusaLink is identified by.
|
||
|
|
a401773406
|
Discover Klipper, PrusaLink and serial printers too
Discovery found only Bambu printers, so a mixed farm still meant typing most of printers.toml by hand. It now covers the four vendors fleet.rs accepts, over both transports. Detection splits in two, and keeping the halves apart is what makes this honest. "Something at this address speaks X" needs no credential from any vendor, and is most of the value - it yields the address and the vendor, which is two of the three or four fields an entry needs. "What is it called, what firmware does it run" only has an answer where the vendor publishes one unauthenticated: Bambu always, Moonraker usually, PrusaLink never. So an HTTP 401 counts as a find rather than a failure. A password prompt from /api/version is proof that something is serving /api/version, which is the question being asked. It also makes the Moonraker probe correct without having to know how a given host configured [authorization], which is not knowable from outside. Klipper is `GET :7125/printer/info`, Moonraker's own identity endpoint, which returns hostname and software_version. PrusaLink is `GET :80/api/version`; its OpenAPI specification puts digestAuth on every operation including /api/v1/info, so there is no unauthenticated identity endpoint at all and a 401 is the best available answer - which is enough, since the only field still missing is the API key no probe could supply. This cannot distinguish PrusaLink from OctoPrint, and that is not fixable from outside: PrusaLink deliberately implements OctoPrint's API. A wrong guess an operator can see and correct beats skipping a real printer. Two guards against claiming things that are not printers, both now tested against what a real LAN actually answers. Three devices on the test segment answer /api/version with HTTP 200 and a body that is not JSON - a router, a device with a logon page, and one serving gzip - so a 200 must carry OctoPrint's guaranteed `api` field, and Moonraker's must carry the `result` wrapper every Moonraker reply has. And a bare 401 is not enough either: routers, NASes and cameras all password protect port 80, so a 401 must carry a *Digest* challenge, which PrusaLink's spec guarantees and the Basic-auth crowd does not send. A sweep of the real /24 still finds exactly the two Bambu printers and nothing else. Serial detection is passive by default, and that is a safety property rather than a limitation. Opening a serial port toggles DTR, which reboots an Arduino-based board - marlin_serial.rs documents the same thing from the other direction - so a firmware handshake against a machine that happens to be printing ruins the print, and discovery is exactly what someone runs while a farm is busy. So list_ports opens nothing: it reads USB descriptors out of sysfs, which is where udev reads them from, and gets the manufacturer, product and USB serial without touching the device. That is enough to render an entry, since a serial printer's block needs only a path and a baud rate. probe_m115 is the opt-in extra that learns the firmware and the exact machine type, and it refuses to run without --yes-reset-the-printer, the same shape as bambu_print_probe's --yes-start-a-real-print. sysfs rather than tokio-serial's libudev feature: a gateway appliance should not need libudev-dev at build time to list its own ports, and reading the four files udev would read is thirty lines and no dependency. The walk climbs to the USB device holding idVendor rather than counting parents, because a ttyACM link points at an interface and a ttyUSB link at a usb-serial port, each a different depth down. Only Prusa's own USB vendor id counts as evidence of a printer. Everything else in the table is a generic bridge chip - FTDI, CH340, CP210x - that a printer is likely to be behind but that a GPS or an Arduino project could equally be, so those are reported with "could be a printer or any other serial device" rather than asserted. Entries now carry exactly the fields each vendor's loader demands and no others, with a test that fails if to_toml_entry and fleet.rs drift apart, and a rendered entry for a vendor whose client is still a stub says so - otherwise an operator pastes in a Klipper printer and gets a gateway that connects and does nothing. Found while testing the M115 parser: a value ran to end-of-input instead of end-of-line, so the last field on a line swallowed what followed and UUID read as "cede2a2f-...\nok". Unverified, and untestable here: the Klipper and PrusaLink probes (no such hardware) and all serial detection (no serial device attached, and /sys/class/tty holds only virtual consoles). Every parser those depend on is unit tested against recorded protocol text, including the real non-printer responses above. |
||
|
|
e4344b208b
|
Find printers on the network instead of retyping their details
Setting up a farm meant reading five fields off each printer's screen into printers.toml, and the serial is the one that punishes a typo: 15 unspaced alphanumerics that address Bambu's MQTT topics, so a wrong character produces a gateway that connects to the broker, subscribes to a topic no printer publishes, and reports nothing. Two mechanisms, because they fail in different places: SSDP (`listen_ssdp`) hears the announcements Bambu printers send to 239.255.255.250 unsolicited, on 2021 and 1990. It learns the most - the model and the operator's own name for the printer come only from here - but multicast does not cross a router, so it finds nothing from a gateway on a different VLAN than its printers, which is an ordinary way to run a workshop. The TLS certificate (`identify`) is the dependable one. Every Bambu printer puts its serial in the subject CN of the certificate it presents on 8883, readable with no credentials, no MQTT session and across subnets. Verified against both real printers: a P1P gives CN = 01S09B441900143 (issuer BBL CA, TLS 1.2) and an H2C CN = 31B8BP5A1800585 (BBL Device CA O1C2-V2, TLS 1.3), each an exact match for what printers.toml already said. A blind sweep of their /24 found exactly those two and nothing else, in 24s. Reading an unverifiable certificate is deliberate and worth being plain about: it is being read as a name tag, not trusted. There is nothing to verify it against - the serial is what is being learned, and a P1P does not chain to the bundled Bambu CA at all. Trust is still decided by BambuTls::resolve and the trust-on-first-connect pinning, where credentials actually get sent. `to_string` and not the deprecated `as_utf8`, which truncates at an interior NUL; `valid_serial` would reject the untruncated form anyway, which is why the shape is checked rather than the name trusted. `entries_by_nid` on the subject specifically, because an issuer's CN sits earlier in the DER and anything scanning for the first CN reports the certificate authority as the printer. Three decisions that are not incidental: It prints a [[printer]] block and does not write printers.toml. Discovery cannot learn an access code - that code is the only thing between anyone on the network and control of the machine - so every block is incomplete by construction, and fleet::load rejects an empty access_code. Writing a half-finished entry in would stop the gateway starting. `vendor = "bambu"`, never a guessed v1/v2. That value auto-detects on connect, and a firmware update can move a physical printer between dialects, so a guess in a file goes stale silently. There is a tempting correlation in the two printers to hand - the v1 machine negotiated TLS 1.2 and the v2 one TLS 1.3 - but two samples is not evidence. A sweep refuses anything larger than a /24. 256 addresses is every printer anyone has on one segment, and a mistyped /8 would be sixteen million connection attempts across somebody's network. The SSDP path has not received a real announcement: the only host available to test from is routed to the printers rather than on their segment, so their multicast cannot arrive. Hence the parser is tolerant - a header spelled differently costs one field, not the printer - and `raw` mode dumps every datagram, so the first run on a real segment is a test that shows its working rather than only its conclusion. openssl is named directly for the CN read. It is already in the tree - native-tls is openssl on Linux - so this adds nothing to the build, and Apache-2.0 passes `cargo deny check licenses`. |
||
|
|
df6dfca3ca
|
Refuse a truncated project, and drive the whole path from the probe
`upload_project_file` already existed - as a `GenericPrinter` trait method, which is why a grep for `pub async fn` missed it and this commit nearly reimplemented it. It logged `written` and `byte_count` next to each other and never compared them, so a short write was something you could only notice by reading the logs afterwards, and the next line printed the truncated file anyway. A `.3mf` is a zip: cut the end off and the central directory goes with it, so the printer gets an archive it cannot open. That is also the failure a slow transfer invites, and this transfer is slow - 4.96 MB took 31.3s, so a 62 MB project is minutes of exposure. `print-project <local> [name]` runs that method against a real printer, so the harness tests the production entry point rather than the three pieces in sequence. It deliberately takes no `--ams`: the whole point is that the mapping comes out of the archive. Gated like `start`, on a terminal state and `--yes-start-a-real-print`. Confirmed end to end on the P1P (2026-10-15, with the owner's go-ahead), with the same project the 2026-10-11 run used: the derivation read one PETG/GFG99/ `#2850E0` filament out of `Metadata/slice_info.config` and produced `mapping=[3]`, padded to five trays; 297,227 bytes went up with an exact byte count; `IDLE -> PREPARE -> RUNNING`. The AMS on that machine has slot 2 in black and slot 3 in blue, same product and same `tray_info_idx`, so picking slot 3 is the colour tie-break doing real work rather than a one-candidate match. |
||
|
|
7d4cf41999
|
Confirm the light and the upload on a real P1P
Four things were shipped unverified because the printer was off when they
were written. Three are now confirmed first-hand (P1P, 2026-10-15), and one
is settled in the opposite direction from what was assumed.
**`set_light` had never once reached a printer**, and `completion::run`
blinks a finished print's chamber light with it. It works - but "accepted" is
not "it changed": `ledctrl` answers `result: "success"` as soon as the
command parses, exactly like the print-control verbs. So `lights_report` is
now modelled on `PrintReport`, which is the only read-back there is, and the
probe polls it rather than printing a reassuring message. Setting the light
on and off reads `[{"node":"chamber_light","mode":"on"}]` / `"off"` back,
about 3s later. The field was observed on v1 even though only the v2 schema
declares it.
**The blink itself works at the rate it ships at.** `completion::celebrate`
is now public so the probe runs the real function instead of a copy: twenty
`ledctrl` commands half a second apart, which a printer is entitled to
refuse. None were refused, it returned after 10.35s, and the light ended
`off` as specified - a blink that leaves the light on would look like a
printer still working.
**The firmware's own `flashing` mode is not the better option.** It is
accepted, and the reply echoes all four parameters back
(`led_on_time`, `led_off_time`, `loop_times`, `interval_time`), so the
printer does parse them. But `lights_report` never reports `flashing` - it
stayed on the previous mode for 12s of polling. A firmware blink is therefore
unobservable: nothing can confirm it happened or tell when it ended, while
the self-driven blink is built from a call that reads back. That is a better
reason to keep `celebrate` than the one in the comment it replaces, which was
that `loop_times` semantics were unconfirmed. Whether the light physically
blinks is still unwitnessed - nobody was watching the machine.
**Multi-MB FTPS upload works, and is slow.** A 4.96 MB project archive went
up with an exact byte count and came back byte-identical (sha256). But it
took 31.3s - about 0.2 MiB/s - so the 62 MB project already on that card
would take six and a half minutes. Anything that uploads a job needs a
timeout budgeted in minutes, not seconds. The claim in `download`'s comment
that these files are "a few hundred KB" is gone; the card disproves it.
Also adds `delete`, because the probe left a 5 MB file on a real SD card and
there was no way to remove it. One explicit path, no globbing: the convenient
version of this deletes something somebody printed from last week. Used to
clean up, and the card is back as it was.
New probe steps: `light on|off|flash`, `blink`, `upload <local> [name]`,
`delete <path>`. 51 tests still pass.
|
||
|
|
13bfec97fe
|
Clear the clippy warnings, except the two that are not cosmetic
Down from 29 warnings to 2, in the spirit of
|
||
|
|
431dd849da
|
Make the filament source explicit, and print from the AMS
`start_uploaded_file` hardcoded `use_ams: false` / `ams_mapping: ""`, which silently overrode whatever the slicer had chosen. On a P1P with an AMS and a project sliced for it, that is not a missing feature - it points the print at the external spool. Confirmed on 2026-10-11: the print started, heated to 250C, reached 1%, then the printer paused itself with `print_error: 50364420` and `tray_now: 255`. Nothing in the command's reply said so; `result` was `success`, because the command had been accepted. So `FilamentSource` is now a required argument with no default, because there is no safe default - picking wrong draws the wrong filament or none. The `ExternalSpool` variant sends the empty *string* the schema's trailing `oneOf` demands, and `ams` takes slots per project filament index and pads to every tray the printer has, per the padding rule in `schemas/bambulab/v1/common/ams/ams_mapping.schema.json`. It refuses an empty mapping (padding `[]` would mean `use_ams: true` with nothing mapped), one longer than the printer has trays, and any negative that is not -1. Confirmed live with the real mapping: `ams_mapping: [3,-1,-1,-1,-1]`, `use_ams: true` took the printer to RUNNING, `tray_now` became 3 - the slot the project was sliced for - and it ran past 1% to 13% with `print_error: 0`, where the external-spool attempt had paused. Finding the mapping needed reading the project back off the card, so FTPS gains `download`/`download_file` and the probe a `fetch` step. The archive's `Metadata/slice_info.config` lists each plate's filaments with `tray_info_idx` and colour - here one PETG GFG99 at `#2850E0`, matching AMS slot 3's `2850E0FF` - and `Metadata/plate_1.gcode` is present, which also confirms the hardcoded `param`. `upload_project_file` is left on the external spool and is the one remaining place that can pick wrong, because it is vendor-generic and an AMS mapping is a Bambu concept. It is unreachable - there is no start-print command on the uplink - and the fix is for it to derive the mapping from the `.3mf` it already holds, which needs a zip reader and so a dependency decision. |
||
|
|
0077e15490
|
Record what a real sliced project did, and widen the start guard
A second live run, this time against a project the owner sliced in Bambu Studio rather than a file already on the card, and through `start_uploaded_file` itself rather than a hand-built body - so the root-vs-cache fix is confirmed end to end. `gcode_file` in the printer's own status came back as `cube-test-2026-10-11.gcode.3mf`, 150 layers, print_type `local`. It also found a defect the first run could not. The print heated to 250C, reached 1%, and then the printer paused itself: `print_error: 50364420` (`0x03008004`), `hms: []`, `tray_now: 255`. 255 is the external spool, which is exactly what the hardcoded `use_ams: false` selects - so that pair overrode the slicer's own filament choice and pointed an AMS-sliced project at an external spool. The first run looked fine only because it was stopped during PREPARE, before filament mattered. The doc comment said that pair was "accepted, and the print ran"; it now says what it actually does, because silently changing which filament a print uses is worse than not supporting AMS at all. The `start` guard demanded IDLE, which meant the harness refused every print following a cancelled one - a Bambu reports an operator cancellation as FAILED. IDLE, FINISH and FAILED are all terminal; PREPARE, RUNNING, PAUSE and SLICING mean the machine is committed, and anything unrecognised is still refused rather than assumed idle. `bambu_cache_list` now prints nozzle/bed temperatures and remaining time. State plus layer number cannot tell a print that is working from one that is stalled: a P1P sits at layer 0 for minutes during bed levelling and purge, and the only thing moving in that window is the heat. |
||
|
|
939c35fb91
|
Confirm the print path on a real P1P, and stop discarding its answer
Print control (pause/resume/stop) and print start are now both confirmed
against the P1P on the LAN, and doing that turned up three real defects.
`start_uploaded_file` published fire-and-forget, so the printer's reply was
thrown away. Asking it to print a file it does not have returned `Ok(())`,
and watching `print.push_status` could not tell that apart from a successful
start, since both leave the machine IDLE for a while. The printer does in
fact answer - `{"command":"gcode_file","param":"...","reason":"error
string","result":"fail"}` - and it echoes the `sequence_id` we send, so
`request` correlates it. Both this and `control_print` now go out as
correlated requests and run the reply through `print_command_outcome`.
The upload and the print command disagreed about where files live. `upload`
cwd'd into `cache/` while the printable projects are in the card's root: the
root holds 43 `<name>.gcode.3mf` archives, `cache/` holds the printer's own
extracted `<project>_plate_N.gcode` working copies with `.gcode.bbl`
sidecars. Those extracted copies are not independently printable -
`gcode_file` with `param: "/cache/Cube_plate_1.gcode"` was rejected for a
file the FTPS listing shows is right there - while `project_file` with
`url: "ftp:///Cube.gcode.3mf"` started a print. So the destination is now a
parameter and both halves point at `SD_ROOT`.
What the hardware settled, recorded in the doc comments: the `ftp:///` url
spelling is right, `param: "Metadata/plate_1.gcode"` works for a
single-plate project, `use_ams: false` + `ams_mapping: ""` is accepted, and
a stop during PREPARE/RUNNING moves the printer to FAILED, which is how
Bambu reports an operator cancellation. What it did not settle: all three
control verbs answer `result: "success"` on an *idle* printer, so the reply
means "accepted", not "the state changed" - callers still have to read
`gcode_state` back.
`PrinterCommand::ControlPrint` makes this reachable from the cloud at all;
until now pause/resume/stop existed in the proxy with no way to send them.
Still no start-print variant, now for a different reason: the path around it
is missing, not the hardware proof.
Also: `list_dir` for any directory (how the layout above was found, without
sending a print command to guess), `request_raw` for probing an unconfirmed
command shape, and two examples - `bambu_cache_list` (read-only) and
`bambu_print_probe` (gated steps, `start` needing both IDLE and
--yes-start-a-real-print).
|
||
|
|
588ca85842
|
Compile the modules once, and clear the warning backlog
`cargo check --all-targets` emitted 32 warnings; it now emits none. Almost all of them came from one cause: main.rs declared `mod config/fleet/printer/uplink` while lib.rs declared the same modules, so every file was compiled twice, once per crate. In the binary copy nothing is externally reachable, so every `pub use` re-export and every method that only an example or a test calls was genuinely dead - and the warnings were real about the binary while being wrong about the library's actual public API. main.rs now uses the library crate and keeps only `mod go2rtc`, which nothing else needs. The rest, individually: - `ModuleInfo` was re-exported from bambu_commands but not from printer, so it was unreachable even though `GetVersionResponse.module` is a public field of type `Vec<ModuleInfo>` - a caller could not name the type of a field it can read. Re-exported rather than dropped. - Three stub `publish` impls take a payload they do not use yet; renamed to `_payload`. - One unused import in examples/test_bambu_certs.rs. That leaves the `async_fn_in_trait` lint on GenericPrinter, which is now `allow`ed with the reasoning written down rather than left to fire on every build. The old comment said it "only matters once this is wired into the multi-threaded daemon", which has since happened - so the question got answered instead of deferred: the futures cannot be required to be `Send`, and that is fine because every printer is reached through one Arc<Mutex<Vec<..>>> from the uplink's own task, so they are created and polled in the same place. The note says what to do if a printer ever gets its own task. No behaviour change. Tests still pass and the daemon was re-verified against the live P1P and H2C through the full backend path. |
||
|
|
9a314b2b9f
|
Fix print.push_status parsing, and stop losing reports silently
Pointed at a real H2C that was 20% into a job, `print_status()` returned
nothing at all. The printer was in fact pushing a full status object every
second; every one was arriving, failing to deserialize, and being dropped
invisibly by an `if let Ok(report) = ..` with no `else`.
That silence produced two confidently-wrong claims in our own comments,
both corrected here:
- `pushall`'s doc said whether v2 emits `push_status` unprompted was "an
open question". It is not: v2 pushes a full 97-field object roughly once
a second from the moment you subscribe, no trigger needed. There is no
missing "other trigger" to hunt for.
- The "sequence gap" warning blamed the network for dropped v1 updates.
Those updates were not dropped in transit - they failed to parse, so
they never reached the counter, making the next one that did look like a
skip. Confirmed: seq 57, 62, 64 and 69 all arrived. After the fix, zero
gaps and zero parse failures across a 25s run against both printers.
Two concrete causes, both found with captured payloads:
- v1 trays carry `tray_temp`/`tray_time`; v2 trays carry
`drying_temp`/`drying_time`. All four were required, so *every* v1 push
carrying AMS data failed.
- A third tray shape existed that nothing modelled: an empty v2 slot sends
`{"id": "2", "state": 0}`, which matched neither `EmptyTray` (it denies
unknown fields, deliberately) nor `LoadedTray` (16 fields short).
A parse failure now reports itself, naming the printer, the sequence id and
the serde error. A report this process cannot parse is a defect in
`PrintReport`, and the only way to fix it is to be told which field.
`PrintReport` itself modelled 9 of 97 top-level fields, and none of them
were progress or temperature - it was built from a truncated example. It
now carries gcode_state, percent, layer counts, remaining time, nozzle/bed
temperatures, fan gears, wifi and HMS entries. `merge_from`'s two dozen
four-line blocks collapse to `newer.x.or(self.x.take())` one-liners: the
old shape made adding a field a three-place edit, and forgetting the merge
half produced a field that silently never survived a partial update.
Two scale traps documented where they bite: reported fan speeds are 0-15
gears, not percent and not the 0-255 PWM we send (`set_fan_speed(50)`
reads back as "7"); and v2 pins `sequence_id` to one value for minutes
while contents change, so it orders and identifies nothing there.
Two examples, and the distinction between them is the point. `live_reports`
is read-only and safe against a printer mid-job. `bambu_idle_checks`
writes, so it requires an explicit printer id and refuses to run unless
that printer reports `gcode_state: "IDLE"`.
Regression fixtures are verbatim captures off both printers, hardware
identifiers scrubbed - the only way to keep this from regressing without a
printer plugged in.
|
||
|
|
305c41993d
|
Update docs and prune examples superseded by real functionality
README/certs/README/.env.example/printers.example.toml were all still describing this as a learning-stage stub with no real printer protocol clients - rewritten to reflect the real Bambu MQTT client, cert auto-pinning, and marlin serial connection that now exist. - Remove examples/fetch_bambu_cert.rs: its manual fetch-and-save workflow is now what BambuPrinter::connect()'s ensure_trusted does automatically on every connect, so it has no remaining use case. - Fix examples/printer_polymorphism.rs, which no longer compiled - dispatch_gcode was replaced by real methods earlier this session; swapped in print_status() as the vendor-only-extension example. - Remove Config::bambu_ca_cert_overrides/bambu_require_valid_cert and the .env vars documenting them - confirmed dead (nothing read them), fully superseded by printers.toml's per-printer ca_cert_path/ require_valid_cert plus automatic trust-on-first-connect pinning. - Fix stale doc comments in printer/mod.rs and printer/bambu.rs that described certificate trust and MQTT as not built yet, or referencing the now-removed example. No behavior change in the daemon itself - verified with cargo build --examples and a live run of printer_polymorphism and auto_connect_bambu against the real P1P/H2C printers. |
||
|
|
6ce60542c6
|
Add pushall + print_status cache; fix envelope, race, and matching bugs
PrintReport now flattens CommandEnvelope (sequence_id/command) - push_status.schema.json composes the shared envelope like every other Bambu message; the struct's old doc comment concluded otherwise from a capture that turned out to be an incomplete example (also missing dozens of other real fields), not proof the message lacks them. Added BambuMqttSession's PrintStatusCache: the in-memory print.push_status object, replaced wholesale on v2 (always full) or on a v1 message with msg != 1 (forced/full), merged field-by-field otherwise (v1's organic partial updates) via PrintReport::merge_from. Tracks last_sequence_id to warn on a gap in the organic stream. BambuPrinter gets pushall() (v1-only; pushing.pushall doesn't exist in v2's schema at all) and print_status(). Three real bugs found and fixed via live testing against an actual P1P, none of them guessable from the schema alone: - pushall's reply doesn't echo the sequence_id we send - the printer stamps its own free-running counter regardless of what triggered it. request()'s ID correlation silently can't work here; first fix attempt added request_next_of_category (wait for the next message under a category, no ID needed). - That undershot too: matching by category alone let an unrelated "print" message (that category carries many commands - gcode_line, pause, push_status, ...) satisfy the wait before the real push_status reply arrived, so pushall() returned Ok having consumed the wrong message - now keyed by (category, command). - A real ordering race: handle_incoming_report woke a waiting oneshot before updating the print_status cache, so a caller could resume and check print_status() before the write landed - pushall() returned Ok immediately followed by print_status() still showing None. Fixed by applying the cache update before sending on any matched oneshot. Superseded by real protocol knowledge before any of the above needed to ship, though: push_status carries its own msg field (1 = automatic/ partial, 0 = forced/full) - the actual, reliable, self-describing signal for which kind a message is, regardless of timing or which client (if any) triggered it. PrintStatusCache now reads that directly instead of inferring it from request correlation, and pushall() is plain fire-and- forget (publish, no wait) since there's nothing left to correlate for - confirmed live: msg reads correctly off a real P1P, and the cache populates/updates correctly with no gap warnings across several organic pushes. request_next_of_category is kept (a future case may still need "no correlation ID at all" for real), just no longer used here. Also: the poll loop now logs when it exits instead of returning silently - that silence is exactly what made a real dropped MQTT connection to a live H2C indistinguishable from "nothing happening" during testing. |
||
|
|
b352fd618d
|
Add upload_project_file/send_gcode_line, real Marlin serial, Bambu protocol auto-detect
- GenericPrinter grows upload_project_file, send_gcode_line, and a generic upload_gcode<P> driver that streams a whole gcode file line by line through any vendor's send_gcode_line. - PrusaSerialPrinter's connect/send_gcode_line are real (not stubs): a held-open MarlinSerialConnection (src/printer/marlin_serial.rs) writes each line and waits for Marlin's "ok" before sending the next. Config changed from com_port: i16 to port: String + baud_rate: u32 to hold a real device path. - Bambu: BambuGenericPrinter + BambuV1Printer/BambuV2Printer collapsed into one BambuPrinter, since which MQTT/BambuMQTT version (v3.1.1/v1 vs v5/v2) a printer speaks is discovered at connect() time (or forced), not something config should pick a type for - the same physical printer can change after a firmware update. printers.toml gets a new "bambu" vendor (auto-detect, the default) alongside bambu_v1/bambu_v2 (force a specific one). - Bambu's gcode_line request is now built for real via continuum-schema-instance against continuum-schemas' JSON Schema, picking the v1 or v2 schema directory based on the detected protocol version, instead of a hand-written serde struct. - Added rumqttc as a dependency (not wired up yet - the real MQTT v5-then-v3.1.1 fallback connect and the publish/receive plumbing are still stubs). |
||
|
|
a2d4e578ec
|
Replace em dashes with hyphens across docs and comments | ||
|
|
1583f531fa
|
Add print.rs (AmsState/AmsUnit/AmsTray/XcamSettings), fix print vs pushing
Mirrors continuum-schemas' schemas/bambulab/ restructuring: PushallResponse removed (it never existed on the wire — pushall's request goes to "pushing", but the state-push stream it triggers arrives under "print", a different root key, not a direct reply). BambuReport::Pushing(...) -> BambuReport::Print(PrintReport). AmsTray is an untagged enum (Empty/Loaded) rather than one struct full of Option<T> fields, matching the JSON Schema's oneOf for the same slot - #[serde(deny_unknown_fields)] on EmptyTray is load-bearing: untagged enums try variants in order, and a loaded tray (superset of Empty's one field) would otherwise incorrectly match Empty first. Verified against the full real ams/xcam example from the conversation via examples/bambu_commands_demo.rs - both the empty and loaded tray in that payload deserialize to the correct enum variant. |
||
|
|
166761479b
|
Replace proto-based bambu_protocol with plain-Rust bambu_commands/
One file per command (get_version.rs, pushall.rs), each holding its request AND response together. CommandEnvelope (sequence_id + command) is the shared-fields piece every command embeds via #[serde(flatten)] — the 'inheritance' replacement for these structs, same composition idea as BambuGenericPrinter in bambu.rs, just expressed as a struct field instead of impl-block delegation. examples/bambu_commands_demo.rs round-trips both commands against Bambu's exact real JSON (from the original conversation) and confirms byte-for- byte matches, same as the removed proto version did — this replacement is behaviorally identical, just without protoc/build.rs in the loop. |
||
|
|
8e5d85202f
|
Wire InfoCommand through as one real, runnable example
BambuRequest::Info(InfoCommand) is now live (was commented out) — examples/bambu_protocol_demo.rs constructs one, serializes it, and prints it next to Bambu's real wire JSON for comparison. Run it and copy this exact shape (proto message -> use it here -> add an enum variant) for every other command. |
||
|
|
6e18215af5
|
Add GenericPrinter::set_fan_speed() across all five printer kinds
Same override pattern as connect(): required, no default body, five completely different bodies. - BambuGenericPrinter::set_fan_speed_impl() is shared by BambuV1Printer and BambuV2Printer (composition reuse, same as connect_impl) - both speak the same MQTT gcode-injection mechanism. - PrusaLinkPrinter and PrusaSerialPrinter both send the same M106 gcode but over different transports (HTTP command injection vs. raw serial bytes) - they share the percent->PWM conversion despite having unrelated connect() implementations. - KlipperPrinter uses a hypothetical Moonraker-native endpoint that takes a percentage directly - no PWM conversion at all, since that math only applies to the gcode-speaking vendors. percent_to_pwm() lives in mod.rs as a private free function rather than a trait default: it's genuine shared logic, but only for the subset of vendors that need it, which is exactly the case a trait default can't express cleanly. Visible to bambu.rs/prusa.rs via super:: because Rust's module privacy reaches into child modules. Verified with cargo check --all-targets and a full run of printer_polymorphism: 50% converges on the same PWM value (127) across all three gcode-based printers, Klipper's native path takes 0.50 directly. |
||
|
|
a77e93940f
|
Fix ensure_trusted(): pin by serial number, not the arbitrary id label
id in printers.toml is just a label you chose for config purposes - nothing ties it to a specific physical printer, and renaming it (or reusing it for a different unit down the line) would silently break the pin lookup and re-trigger trust-on-first-connect for hardware that was already trusted. The serial number is the one thing about a printer that can't change, so that's what a pin should be keyed by: certs/pinned/<sn>.pem instead of certs/pinned/<id>.pem. Verified against a real TLS server: pinned a printer under one id, renamed it in printers.toml with the sn left unchanged, and confirmed the second run found the existing pin silently (no re-TOFU) rather than re-pinning. |
||
|
|
af2f20a45b
|
Add BambuGenericPrinter::ensure_trusted() — smooth auto-connect, SSH-style
The manual fetch_bambu_cert workflow works but needs two commands and a printers.toml edit. ensure_trusted() collapses that into one call, using the same trust model SSH uses for host keys: - a pin already on disk (certs/pinned/<id>.pem) is used directly, no new trust decision is made on every run - no pin yet + bundled CA verifies fine (current-gen printers): nothing to do - no pin yet + bundled CA fails (P1P, etc.): auto-pins via trust-on-first-connect, same as fetch_bambu_cert, but automatic - an *explicit* pin (you set ca_cert_path yourself) never gets silently auto-pinned over — a failure there is a real error examples/auto_connect_bambu.rs demonstrates the one-command flow. Verified all three states against local test servers, not just compiled: first run with no pin auto-pins and connects; second run against the same server is silent (no re-TOFU message) and just verifies against the pin; third run after swapping the server's certificate correctly FAILS instead of silently re-pinning — confirms the security property survives the smoother UX. |
||
|
|
8572d564b1
|
Split BambuPrinter into BambuGenericPrinter -> BambuV1Printer/BambuV2Printer
Completes the GenericPrinter -> BambuGenericPrinter -> BambuV1/V2 chain this project wanted from the start. BambuGenericPrinter holds the fields and behavior every Bambu printer shares (access code, serial number, CA trust, the TLS test/fetch methods); BambuV1Printer and BambuV2Printer each *have* one (composition) and are now genuinely separate types, ready to carry flavour-specific report-schema fields later. Also threads through a new 'sn' (serial number) field the real MQTT topics will need. Adds real 'fetch the CA automatically' capability, verified against a live TLS server (not just compiled): - BambuGenericPrinter::fetch_certificate() does trust-on-first-connect — connects once with verification disabled, captures the certificate the printer actually presents via native_tls's peer_certificate()/to_der(), and returns it as PEM. Deliberately a method you call once by hand (examples/fetch_bambu_cert.rs), not something connect() falls back to silently, since TOFU trusts whoever's on the network the moment you run it. Verified end-to-end against a local openssl s_server: the fetched PEM's SHA-256 fingerprint exactly matched the server's real certificate. - Verified the other direction too: test_bambu_certs (bundled-CA mode) correctly REJECTS that same test server's cert, since it wasn't signed by the real Bambu CA. Splitting BambuV1Printer/BambuV2Printer into distinct types broke the PrinterHandle::BambuV1(x) | PrinterHandle::BambuV2(x) or-pattern in both examples (or-patterns require every alternative to bind the same type) — fixed by giving each variant its own match arm. |
||
|
|
d8b7430296
|
Add printers.toml (gitignored) + real TLS cert test against actual hardware
New: - printers.example.toml (committed template) / printers.toml (gitignored, real hosts + access codes don't belong in git) — a list of real printers with vendor, host, access_code/api_key/com_port, and an optional per-printer CA override. - src/fleet.rs loads that file into ready-to-use PrinterHandles, matching vendor strings to the right constructor. - BambuPrinter::test_tls_handshake() does a real (blocking, one-shot) TLS handshake to port 8883 using that printer's configured BambuTls trust mode — no MQTT protocol, just 'does the certificate verify'. Added native-tls and toml as direct dependencies for this. - examples/test_bambu_certs.rs loads printers.toml and runs the handshake test against every Bambu entry. Also fixes a real bug found while testing against unreachable IPs: plain TcpStream::connect has no timeout and hung indefinitely on an offline printer — switched to connect_timeout (5s). Verified with cargo check --all-targets (0 errors) and by actually running test_bambu_certs against a local printers.toml (correctly errored on a missing cert file, then correctly timed out against unreachable test IPs instead of hanging). |
||
|
|
9eab5e5a04
|
Bambu TLS trust config + finish PrusaLink/PrusaSerial split
Certs: - Vendor Bambu's shared LAN-mode root CA (certs/bambu_ca2.pem, verified self-signed CA:TRUE, see certs/README.md for provenance/fingerprint). - Config gains bambu_ca_cert_path (per-printer override) and bambu_require_valid_cert (the allow/reject flag); printer::bambu::BambuTls turns those into BundledCa/Custom/Insecure. connect() doesn't perform a real handshake yet (no TLS-capable MQTT client wired in), just reports which trust mode it would use. Also reconciles a rename in flight (Printer -> GenericPrinter trait) and finishes the PrusaPrinter -> PrusaLinkPrinter/PrusaSerialPrinter split: added the missing GenericPrinter impl for PrusaSerialPrinter, fixed PrinterHandle's variant payload types, updated mod.rs's pub use list and doc comments, and updated the example to the new 5-variant shape. Verified with cargo check --all-targets (0 errors) and a full run of cargo run --example printer_polymorphism. |
||
|
|
5705f36c01
|
Simplify printer/ module for someone learning Rust
Drop reqwest, RPITIT+Send signature, and multi-variant error enum from the teaching example so the only new idea per file is the trait override itself. Real networking stays in adapters/, unaffected. |
||
|
|
03bd07fbd7
|
Add Printer trait + PrinterHandle enum domain model with polymorphism example |