The edge route had never been run. Adding a way to run it turned up that the server could not start at all, for two independent dependency reasons that typechecking could not see: - `elysia: ^1.1.26` had resolved to 1.4.30, which calls `t.Module` - a TypeBox 0.34 API - while this repo pinned TypeBox 0.33. `t.Module is not a function`. - `drizzle-typebox: ^0.2.1` resolved to a version whose peers demand `drizzle-orm >= 0.36`, against the `^0.33.0` pinned here. Importing it threw `Export named 'getViewSelectedFields' not found`. Both are caret ranges that drifted into combinations nobody chose. elysia, @sinclair/typebox and the drizzle packages are now pinned tightly, TypeBox forward to 0.34.52 (which satisfies Elysia and drizzle-typebox 0.1.1 alike), and tests/dependency_identity.test.ts fails if the TypeBox version ever differs between here and @continuum/ts-types - the skew that made every shared schema invalid, with an error message pointing at Standard Schema instead. Dropping to drizzle-typebox 0.1.1 widens `jsonb` in the generated validators, so `metadata` needs an explicit object shape in validators.ts; the column is declared `$type<Record<string, unknown>>()` and a validated body otherwise is not assignable to `.values()`. scripts/: - `install-docker.sh` - one-time host setup, kept separate because it touches the machine rather than containers. - `dev-env.sh up|down|reset|status|psql|schema|env` - Valkey + Postgres/pgvector. Uses docker-compose.yml when a daemon answers, and otherwise runs the same two services from apt. That fallback is not hypothetical: Docker cannot run in this sandbox at all. dockerd needs CAP_NET_ADMIN to build its bridge; with `--bridge=none --iptables=false` it starts but cannot unpack an image without CAP_SYS_ADMIN; with `--storage-driver=vfs` it still fails because registering a layer needs user namespaces, which are blocked outright. All three are host-level grants, so no script can work around them - hence a second path rather than a broken first one. - `e2e-edge.sh` - the test the unit tests cannot be. Seeds a farm, claims its printers, mints an edge token, runs the real continuum-proxy, and asserts live telemetry reached Postgres and a command reached a printer. It only sends a fan speed, only to a printer reporting IDLE, and puts it back afterwards. - `capture-gateway-frames.js` - records what a gateway really sends, for refreshing tests/fixtures/. Read-only unless FAN_TEST_PRINTER is set. The test comment referred to this before it existed. Verified end to end, from a dropped and freshly migrated database: `h2c` persisted as printing/RUNNING 22% layer 2/25 nozzle 230 bed 35 with 3 HMS alerts, `p1p` as idle/IDLE, and `POST /printers/:id/commands` reached the P1P's fan and came back ok:true. An unclaimed printer is refused 409 PRINTER_UNREACHABLE rather than guessed at. Two things the e2e script got wrong first, both now fixed in it: it waited for the first printer row instead of all of them, which silently tested only the v2 printer (a v1 Bambu reports one tick later); and `$!` after `( cd ... ) &` is the subshell, so cleanup left an orphaned gateway reconnecting with a token for a deleted farm and polluting the next run. Note: `drizzle/` is gitignored, so the generated migration is not committed and there is no migration history in the repo. Left as-is deliberately - that is a workflow call, flagged in PLAN.md.
112 lines
4.6 KiB
TypeScript
112 lines
4.6 KiB
TypeScript
import { describe, expect, it } from "bun:test";
|
|
import { Value } from "@sinclair/typebox/value";
|
|
import { EdgeClientMessageSchema, EdgeServerMessageSchema } from "@continuum/ts-types";
|
|
|
|
import currentCapture from "./fixtures/gateway_frames.json";
|
|
import legacyCapture from "./fixtures/gateway_frames_legacy_nulls.json";
|
|
|
|
/**
|
|
* A contract test, not a unit test: it checks that what continuum-proxy
|
|
* actually puts on the wire is what this backend's validator accepts.
|
|
*
|
|
* The fixtures are real captures from a live gateway talking to a real P1P and
|
|
* H2C, not hand-written examples - which is the whole point. The two ends of
|
|
* /ws/edge/v1 had silently drifted into completely different protocols
|
|
* (different handshake, different telemetry shape, printer ids the gateway
|
|
* could not know), and every hand-written example agreed with whichever side
|
|
* wrote it. Re-capture with scripts/capture-gateway-frames.js when the protocol
|
|
* changes, rather than editing these by hand.
|
|
*/
|
|
|
|
function check(schema: Parameters<typeof Value.Check>[0], value: unknown) {
|
|
const ok = Value.Check(schema, value);
|
|
if (!ok) {
|
|
// Surface *why*, or a failure here is just "false !== true".
|
|
const errors = [...Value.Errors(schema, value)].map(
|
|
(e) => `${e.path || "/"}: ${e.message} (got ${JSON.stringify(e.value)})`,
|
|
);
|
|
throw new Error(`validation failed:\n ${errors.join("\n ")}`);
|
|
}
|
|
}
|
|
|
|
describe("gateway -> backend frames", () => {
|
|
for (const frame of currentCapture.frames) {
|
|
it(`accepts a real '${frame.type}' frame`, () => {
|
|
check(EdgeClientMessageSchema, frame);
|
|
});
|
|
}
|
|
|
|
it("accepts the pre-fix capture, where empty fields were explicit nulls", () => {
|
|
// Liberal reader: the gateway now omits these, but a serde-derived
|
|
// producer emits null by default and one such field must not cost us a
|
|
// whole farm's telemetry batch.
|
|
for (const frame of legacyCapture.frames) {
|
|
check(EdgeClientMessageSchema, frame);
|
|
}
|
|
});
|
|
|
|
it("carries the live telemetry this was captured from", () => {
|
|
const telemetry = currentCapture.frames.find((f) => f.type === "telemetry");
|
|
expect(telemetry).toBeDefined();
|
|
const printers = (telemetry as { printers: Array<{ printer_id: string }> }).printers;
|
|
expect(printers.length).toBeGreaterThan(0);
|
|
// Guards against a fixture that validates because it is empty.
|
|
expect(printers.every((p) => typeof p.printer_id === "string" && p.printer_id.length > 0)).toBe(true);
|
|
});
|
|
|
|
it("rejects a telemetry batch whose printer has no id", () => {
|
|
// printer_id and name are the only required fields; everything else is
|
|
// genuinely unknowable for a printer that has only just connected.
|
|
check(EdgeClientMessageSchema, { type: "telemetry", printers: [{ printer_id: "p1p", name: "P1P" }] });
|
|
expect(Value.Check(EdgeClientMessageSchema, { type: "telemetry", printers: [{ name: "P1P" }] })).toBe(false);
|
|
});
|
|
|
|
it("rejects an unknown message type", () => {
|
|
// The old protocol's handshake, which no gateway ever sent.
|
|
expect(Value.Check(EdgeClientMessageSchema, { type: "auth", token: "x" })).toBe(false);
|
|
});
|
|
});
|
|
|
|
describe("backend -> gateway frames", () => {
|
|
// Exactly what src/routes/ws/edge.ts sends. If one of these stops
|
|
// validating, the gateway's serde enum will have stopped accepting it too -
|
|
// see the mirror of this test in continuum-proxy/tests/uplink_protocol.rs.
|
|
const outbound = [
|
|
{ type: "hello_ack", session_id: "3f2b1c5e-0000-4000-8000-000000000000" },
|
|
{ type: "hello_error", message: "invalid edge token" },
|
|
{ type: "heartbeat_ack", seq: 7 },
|
|
{
|
|
type: "command",
|
|
command_id: "9a7d2f10-0000-4000-8000-000000000000",
|
|
printer_id: "p1p",
|
|
command: { action: "set_fan_speed", percent: 40 },
|
|
},
|
|
{
|
|
type: "command",
|
|
command_id: "9a7d2f11-0000-4000-8000-000000000000",
|
|
printer_id: "p1p",
|
|
command: { action: "send_gcode_line", line: "M106 S0" },
|
|
},
|
|
];
|
|
|
|
for (const frame of outbound) {
|
|
it(`emits a valid '${frame.type}' (${(frame as { command?: { action: string } }).command?.action ?? "no command"})`, () => {
|
|
check(EdgeServerMessageSchema, frame);
|
|
});
|
|
}
|
|
|
|
it("has no start-print command to send", () => {
|
|
// Deliberate: the gateway can start an uploaded file, but that path has
|
|
// never been run against real hardware. Delete this test when it has been,
|
|
// and add the variant to the schema.
|
|
expect(
|
|
Value.Check(EdgeServerMessageSchema, {
|
|
type: "command",
|
|
command_id: "x",
|
|
printer_id: "p1p",
|
|
command: { action: "start_print", file_name: "plate_1.3mf" },
|
|
}),
|
|
).toBe(false);
|
|
});
|
|
});
|