901d5e9748f8332c8dc460b1b49edd9ed4b88bfa
7
Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
901d5e9748
|
Execute start_print, and never await it on the uplink task
The gateway can now run a cloud-dispatched print: download the job file from the presigned URL in the command, then hand it to the existing `upload_project_file`, which derives the filament mapping from the archive, transfers it over FTPS and starts it. ## The download refuses to be a weapon `src/uplink/download.rs` checks the HTTP status before reading a byte, because an expired presigned URL answers 403 with an XML error document and writing *that* to a printer as a project is the worst outcome available. It rejects a `Content-Length` over 256 MiB before reading, and enforces the cap while streaming as well, so a server that lies or omits the length cannot make a small gateway box buffer until the OOM killer arrives. A byte count that disagrees with `Content-Length` is an error: a `.3mf` is a zip, and a truncated one loses the central directory the printer needs. HTTPS only, no redirects, and the URL is stripped from error messages. `PrinterCommand` no longer derives `Debug` for the same reason - `dispatch` logs every command, and a presigned URL is a bearer credential until it expires. It prints as `<redacted>`. ## Why it is spawned `start_print` is the one command that cannot be answered inline, and the reason is not latency. Everything else here is an MQTT publish returning in milliseconds. This downloads tens of megabytes and then transfers them at a measured 0.2 MiB/s - about four minutes for a 50 MB project - and awaiting that inside the uplink's `select!` loop stops heartbeats and, far worse, stops telemetry for the duration. No telemetry is what makes spawning mandatory rather than tidy. The cloud now derives a job's state from the telemetry that follows a start, so a gateway that goes silent for four minutes during every job start withholds exactly the information the job depends on - while the backend times the command out after ten seconds and concludes the start failed. The job would be requeued onto a printer that was busy printing it. So the `ok` means "accepted, working on it", which is all a start reply was ever trusted to mean. `runs_for_minutes` is an exhaustive match rather than a `matches!`, so a new variant has to make that choice instead of defaulting to the stall. The gap this leaves is honest and recorded in the code: a failure after the ack has no `CommandResult` to travel on, because answering later needs an outbound channel this loop does not have. Until it does, the gateway's log is where the reason lives and the backend reaps the job. reqwest 0.12 with `rustls-tls-native-roots`, not 0.13: 0.13 pulls `webpki-root-certs` under CDLA-Permissive-2.0, which is not on the allow list, and `aws-lc` brings OpenSSL-licensed C. `cargo deny check licenses` passes. 54 tests. |
||
|
|
254798e8cb
|
Model vt_tray and the stage fields, and use them
## vt_tray closes a hole in the filament decision
`filament_source_for` used to refuse a project that wanted the external
spool, on a printer that had an AMS, purely because there was no way to see
what the spool held - and claiming a match without looking is how the
`use_ams: false` bug happened. Now that `vt_tray` is on `PrintReport`, the
question can be answered: `external_spool_satisfies` reuses `map_to_trays`
with the spool as the single candidate tray, so an `Ok` means every filament
matched it.
The decision is now: the AMS first when there is one, because a project
sliced for the AMS should use the AMS even if the spool happens to hold the
same filament; the spool if nothing in the AMS fits and the spool does; and
an error otherwise, reporting the AMS mismatch rather than the spool one
since that names what was wanted against what was loaded. A reported spool
that does not match is a real negative now and is refused.
One case stays unverifiable: a v2 printer reporting neither AMS trays nor
`vt_tray`. v2 omits the key entirely, so absence means "not reported", not
"empty". That one is logged as an unverified assumption instead of being
passed off as a match - and it is the same reason `EXTERNAL_SPOOLS` is still
a constant. Counting reported spools would give 0 on exactly the printer the
ams_mapping schema says has two.
Tests use the real P1P capture's own spool (PETG P9599a25 in D3C5A3FF): it
satisfies a project asking for that filament, and does not satisfy one asking
for the AMS's blue GFG99. Those two were indistinguishable before.
## stage reaches the cloud
`stg_cur`/`stg` are modelled, and `stage` is now on `PrinterTelemetry`,
through `continuum-schemas` and the ts-types mirror. Without it progress is
ambiguous in a way that reads as a fault: on the confirmed P1P run `percent`
climbed to 14% while `layer` stayed 0 for minutes, the printer walking
`stg_cur` 54 -> 14 -> 13 -> 0 before laying the first layer. A console
showing 14% at layer 0 with no stage looks stuck.
A zero stage means "printing" and has its own test on both sides, because
`skip_serializing_if = "Option::is_none"` plus one `unwrap_or_default` is all
it takes to turn "printing" into "no stage".
The backend test asserts a *wrongly typed* stage is rejected, not just that a
valid one is accepted: `PrinterTelemetrySchema` permits unknown properties -
verified - so `{ stage: 54 }` validates whether or not the field is declared.
The negative is what fails if someone removes it.
The live capture fixture is left alone. It predates the field, the field is
optional, and editing a capture by hand would defeat the point of having one.
|
||
|
|
939c35fb91
|
Confirm the print path on a real P1P, and stop discarding its answer
Print control (pause/resume/stop) and print start are now both confirmed
against the P1P on the LAN, and doing that turned up three real defects.
`start_uploaded_file` published fire-and-forget, so the printer's reply was
thrown away. Asking it to print a file it does not have returned `Ok(())`,
and watching `print.push_status` could not tell that apart from a successful
start, since both leave the machine IDLE for a while. The printer does in
fact answer - `{"command":"gcode_file","param":"...","reason":"error
string","result":"fail"}` - and it echoes the `sequence_id` we send, so
`request` correlates it. Both this and `control_print` now go out as
correlated requests and run the reply through `print_command_outcome`.
The upload and the print command disagreed about where files live. `upload`
cwd'd into `cache/` while the printable projects are in the card's root: the
root holds 43 `<name>.gcode.3mf` archives, `cache/` holds the printer's own
extracted `<project>_plate_N.gcode` working copies with `.gcode.bbl`
sidecars. Those extracted copies are not independently printable -
`gcode_file` with `param: "/cache/Cube_plate_1.gcode"` was rejected for a
file the FTPS listing shows is right there - while `project_file` with
`url: "ftp:///Cube.gcode.3mf"` started a print. So the destination is now a
parameter and both halves point at `SD_ROOT`.
What the hardware settled, recorded in the doc comments: the `ftp:///` url
spelling is right, `param: "Metadata/plate_1.gcode"` works for a
single-plate project, `use_ams: false` + `ams_mapping: ""` is accepted, and
a stop during PREPARE/RUNNING moves the printer to FAILED, which is how
Bambu reports an operator cancellation. What it did not settle: all three
control verbs answer `result: "success"` on an *idle* printer, so the reply
means "accepted", not "the state changed" - callers still have to read
`gcode_state` back.
`PrinterCommand::ControlPrint` makes this reachable from the cloud at all;
until now pause/resume/stop existed in the proxy with no way to send them.
Still no start-print variant, now for a different reason: the path around it
is missing, not the hardware proof.
Also: `list_dir` for any directory (how the layout above was found, without
sending a print command to guess), `request_raw` for probing an unconfirmed
command shape, and two examples - `bambu_cache_list` (read-only) and
`bambu_print_probe` (gated steps, `start` needing both IDLE and
--yes-start-a-real-print).
|
||
|
|
ca3846b7c7
|
Make the uplink match the written protocol, and test that it does
Adds tests/uplink_protocol.rs, the gateway half of a contract test whose other half is continuum-backend/tests/edge_protocol.test.ts. It checks that every message the backend sends is one this gateway can read, and that what this gateway writes is what the schema says it writes. It found two things immediately. Telemetry was serializing empty fields as explicit nulls. serde emits `"job_name": null` for an empty Option unless told otherwise, and the backend's validator treats a missing key and an explicit null as different things - so every batch containing an idle printer, which by definition has no job name, would have been rejected whole. Every optional field now has skip_serializing_if, confirmed against a live capture: an idle P1P's snapshot has no nulls in it at all. ServerMessage had no variant for the handshake being rejected. A bad or expired token would have arrived as "unparseable message from cloud, ignoring" and then been retried every five seconds forever, which in the logs is indistinguishable from a network fault. HelloError is now a real variant, logged at error level naming the env var to go fix, and it stops the connection attempt instead of looping on it. Also exposes config and uplink from lib.rs so the test can reach them, same reason fleet and printer are already there. Verified live against a P1P and an H2C for the whole run, including the H2C finishing its print: RUNNING 98% -> FINISH 100% layer 50/50 with the nozzle cooling 84C -> 76C, all of it arriving through the uplink, no warnings. |
||
|
|
91fbcaf665
|
Route telemetry up and commands down over the cloud uplink
The proxy did not actually proxy. `fleet` was loaded and connected in main.rs and then never touched again, while the uplink said hello and sent heartbeats into the void - two halves of the program running side by side with nothing between them. Both directions are wired now. Up: every 5s, one vendor-neutral `PrinterTelemetry` snapshot per printer that has reported, batched into a single `Telemetry` message. The snapshot is a translation rather than a forwarded `print.push_status`, because it has to describe a Prusa too, and because Bambu's wire format has traps (0-15 fan gears, ints-or-floats temperatures) that should not reach the rest of the system. Down: a `Command` is looked up by our own printer id, executed, and answered with a `CommandResult`. `PrinterCommand` is deliberately small and deliberately has no "start a print" variant - `start_uploaded_file` has never been run against hardware, and the first thing to exercise it should be a human watching the machine, not a message from the internet. The fleet becomes `Arc<Mutex<Vec<PrinterHandle>>>` so main and the uplink can share it. One lock for the whole Vec is coarse - a slow command to one printer stalls telemetry for all of them - which is fine at a handful of printers and is the shape to revisit (a lock per printer, or an actor task each) before a farm gets large. Two things found by running this against the live P1P and H2C: - A v1 Bambu reached the cloud as a row of nulls with one real bed temperature in it, while the v2 H2C beside it was fully populated. v1 only sends a *complete* status when asked, and `pushall`'s own doc comment said to call it periodically - nothing ever did. Each telemetry tick now collects, then requests the next refresh, so v1 telemetry runs one tick behind instead of staying stuck on fragments. The quirk lives in `PrinterHandle::refresh_status` so the uplink does not have to know it. - The third instance of the silent-swallow parse bug, at the old uplink/mod.rs:63: `if let Ok(server_msg) = serde_json::from_str(..)` with no else. Same shape that hid broken `print.push_status` parsing for weeks, except here it would mean commands vanishing with the cloud never being told. Now a `match` with a loud `Err` arm. Verified end to end against both printers with a throwaway WebSocket server: H2C `RUNNING 88% layer 48/50 13min nozzle 230/230 bed 35/35`, P1P `IDLE 0% nozzle 23.5/0 bed 22.5/0`, both fan commands `ok=true`, zero warnings over 24s. |
||
|
|
d0a17ee50e
|
Simplify boilerplate for learning: drop real protocol code, minimal main.rs
Removed adapters/ (rumqttc MQTT, suppaftp FTPS, reqwest HTTP), plate_changer/ (tokio-serial), discovery/, and cache.rs (rusqlite) — src/printer/ already covers 'talk to a printer' as simple stubs, so keeping a second, more complex version alongside it was redundant. main.rs goes from 6 concurrent tasks to 2 (uplink + go2rtc). uplink/ drops channels, jitter, and Send-bound futures. Verified with cargo build + cargo run --example printer_polymorphism. |
||
|
|
2807b2b067
|
Initial boilerplate scaffold for continuum-proxy |